THECHNICAL DATA  
 
  Video system   PAL, picture elements:752(H) x 582(V), fixed focus     Stroke of retraction
device
  700 mm
 

Thermography from total radiation

  Temperature range
1000°C – 1800°C
    Field cabinet   600 x 380 x 210 mm (HxWxD)
  Optical alignment   Sensor 0°: axially-parallel to
sensor axis,
Sensor45°: angled 45° to
sensor axis
    Cable length   Sensor/Retraction – Field control
cabinet 10 m
  Optical field of view   Sensor 0°: horizontal 72°, vertical 54°,diagonal 90°;Sensor 45°:
horizontal 48°, vertical 36°,
diagonal 60°
    System PC   19" industrial housing, 4 HE,
depth 450 mm
  Data interfaces on
the system PC
  RS232, RS422, RS485:
ASCII, MODBUS, Siemens RK512;
Ethernet: TCP/IP: FTP, MODBUS
    Weights   Sensor with retraction and
carrier 70 kg,
Field control cabinet 15 kg
  Auxiliary energy   230 V / 50 Hz, 500 VA    

Cooling water volume

  350 l/h, 1.5…8 barg
  Gas temperature in
combustion chamber
  Water-cooled sensor
<1800°C
    Cooling water
temperature
  Inlet: <45°C, Outlet: Temperature
increase <10° C
  Ambient
temperature
  Sensor / Retraction: 0°C…60°C,
Field control cabinet: 0°C…45°C
    Cooling water quality   Clean, chemically neutral,
non-corrosive,
Hardness: <5°dH / <28 mMol/l
  Material   Sensor: stainless steel 1.4571 /
1.4301, Field control cabinet:
steel sheet, painted in RAL 7035
    Compressed air volume   max. 25 Nm3/h
  Dimensions / Weights   Diameter of sensor tip:
water-cooled 43 mm
    Compressed air
pressure
  5 – 8 barg
  Immersion depth in combustion chamber   max. 450 mm
from welding plate
    Compressed air
temperature
  5…40°C
  Space requirement
for sensor / retraction device
  1450 x 500 x 800 mm (LxWxH)     Compressed air quality   dry, free from dust, aerosols, oil
 
     
     
 
 